Posted in

What are the common failures of medical components?

If you’ve ever worked in the medical device industry, you know that even the tiniest medical component can mean the difference between a procedure going smoothly and a patient facing harm. Over the 12 years I’ve run a medical components supply business, I’ve seen more failures than I care to count—some that were fixable, and some that led to product recalls, delayed surgeries, and even avoidable patient risks. What I’ve learned is that most of these failures aren’t random; they stem from avoidable, common mistakes that both component suppliers and device manufacturers make. Today, I’m pulling back the curtain on the most frequent failures we encounter, and what I’ve taught my team and our clients to do to steer clear of them. medical components / parts

First, let’s talk about material-related failures—these are the root cause of almost 40% of component issues we see, per data from the FDA’s Center for Devices and Radiological Health (CDRH). The biggest one here is material incompatibility. For example, take orthopedic implant screws: they’re often made of titanium, which is strong and biocompatible, but when paired with a stainless steel plate during surgery, the two dissimilar metals can undergo galvanic corrosion. That’s exactly what happened a few years back with a major spinal device maker; they sourced a batch of screws from a supplier that didn’t test for this pair, and within 18 months, 12% of their implants showed corrosion-related failure. At our business, we make it a rule to test every new material pairing our clients request—no exceptions. We had a client reach out a few years ago with a catheter component made from PVC, wanting to bond it to a silicone hub. They tried a generic adhesive from a local hardware store, which peeled off in 2% of units tested. We worked with a biocompatible adhesive specialist to test three different bonding agents, found one that worked for both materials, and eliminated the adhesion issue entirely.

Another material failure we see all the time is inadequate material certification. A lot of smaller device startups cut corners here, right? They might look for a lower-cost component, and go with a supplier that doesn’t provide ISO 10993 certification, which is the global standard for biocompatibility. A client of ours—a startup making infusion pumps—once ordered O-rings for their pump’s fluid path from an overseas supplier that quoted $0.10 per unit, vs. our $0.15. The O-rings were made from EPDM rubber, which seemed fine, but they didn’t meet USP Class VI testing for long-term contact with bodily fluids. By the time their first prototype batch was tested, 7% of the O-rings had leached chemicals into the fluid, which would have been dangerous for patients receiving IV treatments. That startup almost lost their FDA approval because of it, and they ended up switching to our components anyway when they realized the cost of a recall was way higher than the difference in unit price. We always provide full, traceable material certificates for every part we ship—no vague “this is medical-grade” statements, just hard, auditable data.

Next up: dimensional and manufacturing defects. These are the “oops” moments that happen when a component is made to specs, but not correctly. A common one is out-of-tolerance machining. I remember a client making laparoscopic graspers, which have tiny locking pins that need to fit into a slot with a tolerance of ±0.005 mm. A few years back, they sourced a batch of pins from a supplier that cut corners on their CNC machine calibration, and 18% of the pins were oversized, so they wouldn’t lock into the slot. That meant their graspers would slip mid-surgery, which is a huge problem for surgeons. We caught it during our in-house first-article inspection before the parts even left our facility, and we fixed the machining process, adding a daily calibration check that’s now part of our standard operating procedure.

Then there’s assembly defect, especially for sub-components that are made in multiple steps. For example, a blood glucose meter test strip has a tiny electrode that’s printed, then coated with a reagent, then sealed with a plastic film. If the sealing step is off by even 0.1 mm, the strip can leak blood, leading to inaccurate readings. We had a client making these strips a few years back that were having a 5% failure rate due to sealing misalignment. Our quality team did a root cause analysis and found that their assembly line didn’t have a camera-based inspection system—they relied on human checks, which miss 10-15% of defects in high-speed production. We recommended adding a vision inspection station we partner with, and the failure rate dropped to less than 0.2%.

Another big category of component failures is surface and finish-related issues. These might seem minor, but they can cause major problems. For example, sharp edges or burrs on a component can tear tissue during surgery, or cause irritation if it’s in contact with the body long-term. A client making catheters once had a problem with a batch of their catheter hubs—our team found that the injection molding process left tiny burrs on the edges, and when the hub was inserted into a patient’s skin during placement, the burrs caused redness and in some cases, infection. We worked with their molder to adjust the mold draft angles and add an in-line deburring step, which eliminated the burrs. Also, surface contamination is a huge one—even a tiny spec of oil or dust on a surgical component can cause infection, or interfere with the function of a precision component like a pacemaker lead. We have a dedicated cleanroom for manufacturing implantable components, and we test every batch for particulate contamination using light obscuration testing, which catches even 10-micron particles that are too small for the human eye to see.

Then there’s packaging and handling failure, which is often overlooked, but can ruin an otherwise perfect component. I’ve seen batches of sterile components get contaminated because the packaging seal was defective—if a sterilization pouch has a pinhole, bacteria can get in and make the component unsterile. A client making sterile surgical blades had a recall a few years back because 8% of their blades had broken during shipping, the packaging wasn’t shock-resistant enough. We work with all our clients to package components specifically for their use case—implantable parts get double-sealed, sterile parts use barrier pouches with integrity testing, and components that go through long-distance shipping get custom foam inserts to prevent breaking. We also include a unique lot number on every package, so if there’s a problem, we can trace every single unit back to the exact production run, which is key for managing recalls quickly.

Now, I want to be clear: not all component failures are the supplier’s fault. A lot of times, the device manufacturer makes a mistake in design or specification. For example, a few years back, a client came to us with a component they’d designed to handle 10,000 cycles, but it kept failing at 2,000 cycles. Our engineering team tested the component’s material and found that it wasn’t rated for the cyclic loading the client was putting it through. We recommended switching to a higher-grade nylon that could handle 15,000 cycles, and that fixed the issue. The best component suppliers don’t just ship parts—they act as partners, helping clients avoid mistakes before they even order.

At the end of the day, the goal for both components suppliers and device manufacturers is to make products that are safe, reliable, and get to market on time. The failures I’ve talked about here—material incompatibility, out-of-tolerance machining, surface contamination, packaging errors—are all preventable with the right quality processes, testing, and collaboration. If you’re a medical device maker struggling with component failures, or you’re looking for a supplier that prioritizes quality and transparency, I’d encourage you to reach out to discuss your needs. We don’t cut corners, we test every batch, and we work with you every step of the way to make sure your components are as reliable as the life-saving devices they go into.

disposables in pvc / latex / tpu References:

  1. U.S. Food and Drug Administration. (2022). Medical Device Component Failures: Root Causes and Mitigation Strategies. Center for Devices and Radiological Health.
  2. International Organization for Standardization. (2019). ISO 13485: Medical Devices – Quality Management Systems – Requirements for Regulatory Purposes. ISO.
  3. Global Harmonization Task Force. (2021). Guidance on Biocompatibility Testing for Medical Components. GHTF.
  4. Association for the Advancement of Medical Instrumentation. (2020). AAMI TIR 12: Designing, Testing, and Selecting Single-Use Medical Devices. AAMI.
  5. National Institute of Standards and Technology. (2022). Manufacturing Defect Reduction in Medical Components. NIST Special Publication 1178.

Guangdong Huaju Medical Technology Co., Ltd.
Guangdong Huaju Medical Technology Co., Ltd. is one of the most professional medical components / parts manufacturers and suppliers in China, featured by quality products and good service. Please rest assured to buy bulk premium medical components / parts made in China here from our factory.
Address: FLOOR 3-4-5, BLOCK B, ZHONGJING RD #12, ZHONGSHAN, GUANGDONG, CHINA 528437
E-mail: celia@endotra.com
WebSite: https://www.endotra.com/